Что происходит, когда сгорает диск в raid ?
Автоматически приходят системные уведомления от ОВХ
FailSpare event on /dev/md2:ns390332
Идем в API
eu.api.soyoustart.com/
Делаем запрос на замену
И получаем замену
FailSpare event on /dev/md2:ns390332
smartctl /dev/sda -a
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.4.83-1-pve] (local build)
Copyright © 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi/HGST Ultrastar 7K4000
Device Model: HGST HUS724030ALA640
Serial Number: PN1234P9G0B1VX
LU WWN Device Id: 5 000cca 248c02984
Firmware Version: MF8OABY0
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Wed Jun 27 01:35:03 2018 MSK
SMART support is: Available — device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 24) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 452) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always — 0
2 Throughput_Performance 0x0005 136 136 054 Pre-fail Offline — 80
3 Spin_Up_Time 0x0007 167 167 024 Pre-fail Always — 398 (Average 350)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always — 50
5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 2003
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always — 0
8 Seek_Time_Performance 0x0005 145 145 020 Pre-fail Offline — 24
9 Power_On_Hours 0x0012 097 097 000 Old_age Always — 24093
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always — 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always — 46
192 Power-Off_Retract_Count 0x0032 096 096 000 Old_age Always — 4952
193 Load_Cycle_Count 0x0012 096 096 000 Old_age Always — 4952
194 Temperature_Celsius 0x0002 111 111 000 Old_age Always — 54 (Min/Max 18/66)
196 Reallocated_Event_Count 0x0032 001 001 000 Old_age Always — 2741
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always — 2
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline — 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always — 0
SMART Error Log Version: 1
ATA Error Count: 149 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It «wraps» after 49.710 days.
Error 149 occurred at disk power-on lifetime: 24092 hours (1003 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
— — — — — — — 40 51 02 26 1e 36 01 Error: UNC 2 sectors at LBA = 0x01361e26 = 20323878
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
— — — — — — — — — — c8 00 08 20 1e 36 e1 08 3d+08:39:12.591 READ DMA
c8 00 08 18 1e 36 e1 08 3d+08:39:12.590 READ DMA
c8 00 08 10 1e 36 e1 08 3d+08:39:12.590 READ DMA
25 00 08 f0 d3 28 e0 08 3d+08:39:12.590 READ DMA EXT
c8 00 08 08 1e 36 e1 08 3d+08:39:12.590 READ DMA
Error 148 occurred at disk power-on lifetime: 24092 hours (1003 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
— — — — — — — 40 51 ba 26 1e 36 01 Error: UNC 186 sectors at LBA = 0x01361e26 = 20323878
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
— — — — — — — — — — c8 00 00 e0 1d 36 e1 08 3d+08:39:09.735 READ DMA
c8 00 00 e0 1c 36 e1 08 3d+08:39:09.734 READ DMA
c8 00 00 e0 1b 36 e1 08 3d+08:39:09.733 READ DMA
c8 00 00 e0 1a 36 e1 08 3d+08:39:09.732 READ DMA
c8 00 00 e0 19 36 e1 08 3d+08:39:09.731 READ DMA
Error 147 occurred at disk power-on lifetime: 24092 hours (1003 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
— — — — — — — 10 51 d0 30 1d 36 01 Error: IDNF 208 sectors at LBA = 0x01361d30 = 20323632
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
— — — — — — — — — — 35 00 00 00 1a 36 e0 08 3d+08:20:03.471 WRITE DMA EXT
ef 10 02 00 00 00 a0 08 3d+08:20:03.471 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 08 3d+08:20:03.471 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 08 3d+08:20:03.468 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 3d+08:20:03.468 SET FEATURES [Set transfer mode]
Error 146 occurred at disk power-on lifetime: 24092 hours (1003 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
— — — — — — — 10 51 cd 33 1d 36 01 Error: IDNF 205 sectors at LBA = 0x01361d33 = 20323635
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
— — — — — — — — — — 35 00 00 00 1a 36 e0 08 3d+08:20:00.734 WRITE DMA EXT
ef 10 02 00 00 00 a0 08 3d+08:20:00.733 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 08 3d+08:20:00.733 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 08 3d+08:20:00.731 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 3d+08:20:00.731 SET FEATURES [Set transfer mode]
Error 145 occurred at disk power-on lifetime: 24092 hours (1003 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
— — — — — — — 10 51 cd 33 1d 36 01 Error: IDNF 205 sectors at LBA = 0x01361d33 = 20323635
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
— — — — — — — — — — 35 00 00 00 1a 36 e0 08 3d+08:19:58.049 WRITE DMA EXT
ef 10 02 00 00 00 a0 08 3d+08:19:58.048 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 08 3d+08:19:58.048 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 08 3d+08:19:58.046 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 3d+08:19:58.045 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 15781 — # 2 Short offline Completed without error 00% 9703 — # 3 Short offline Completed without error 00% 9697 — # 4 Short offline Completed without error 00% 9697 — # 5 Short offline Completed without error 00% 9117 — # 6 Short offline Completed without error 00% 9104 — # 7 Short offline Completed without error 00% 9104 — # 8 Short offline Completed without error 00% 9100 — # 9 Short offline Completed without error 00% 9087 — #10 Short offline Completed without error 00% 9087 — #11 Short offline Completed without error 00% 9081 — #12 Short offline Completed without error 00% 9068 — SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Идем в API
eu.api.soyoustart.com/
Делаем запрос на замену
И получаем замену
0 комментариев